① Fundus BIN (Identificatio Fundi Normalis) technologiam ignorat.
② Analysator multispectralis MCA, algorithmus statisticus SIGMA characteristicus
③ Functio NORM (40K) Cito discernere inter nuclida artificialia et naturalia communia (e.g.40K.232Th)
④ Functio recognitionis nuclidorum (cum specillo natrii iodidi / facultativa)
⑤ Detector iodidi natrii et analysator spectrometris energiae multicanalis MCA coniunctis accurate distinguere potest inter nuclida medica, nuclida industrialia, et radionuclida naturalia.
Nuclidum naturale | 40K.226Ra,232Th |
Nuclidum industriale | 241Sum,137Cs.60Co.57Co.22Na,133Ba,54Mn,88Y |
Nuclida medica | 131Ego,201Tl,203Mercurium18F.99mTc,99Mo,192Ir |
Materiae nucleares speciales | 57Co.CLIIEu,238U |
⑥ Celeritate maxima selectionis (celerrima: 200ms)
nomen propositi | Informationes parametrorum |
Genera detectorum | Lamina scintillatoria plastica + tubus photomultiplicator sonitus humilis |
Volumen detectoris | 5, 10, 15 cum duplici specillo ad libitum (praedefinita ianuae specillo duplici) |
Maxima ratio transitionis | 106cps |
ambitus energiae | 25keV ~ 3MeV |
sensibilitas | m5000cps / (Sv / h) (10 L, relativum)137Cs) |
Limes inferior detectionis | Facultas detegendi radiationem supra fundum 5nSv/h |
Optionalis unus, tubus neutronicus |
|
Recognitio dinnuclidorum optionalis |
|
1. Efficacia detectionis staticae (AB)
A. Efficacia detectionis staticae systematis monitorii pedestris
fons radioactivus | Energia principaliskeV | Efficacia detectionis staticae | Dosis ad 1.5m / (nSv.h)-1/MBq | |
s-1/MBq | s-1/(nSv.h-1) | |||
241Am | 60 | ≥220 | ≥94 | 2.3 |
57Co | 122,136 | ≥840 | ≥90 | 9.3 |
137Cs | DCCLXII | ≥960 | ≥23 | 42 |
60Co | 1173,1332 | ≥1800 | ≥11 | CLX |
133Ba | 3,181,302,356 | ≥1680 | ≥73 | 23 |
infunde:
1. Fons probationis neutronicae 252Cf cum fonte neutronico forti 12000/s (1 ± 20%) in loco puncti referentiae detectoris collocatur.
2. Frequentia numerationis neutronum requisito frequentiae numerationis > 100 (1 ± 20%) / s satisfacere debet.
Efficacia detectionis staticae systematis monitorii fasciculi B-row
fons radioactivus | Energia principaliskeV | Efficacia detectionis staticae | Dosis ad 1.5m / (nSv.h)-1/MBq | |
s-1/MBq | s-1/(nSv.h-1) | |||
241Am | 59.5 | ≥480 | ≥92 | 5.2 |
57Co | 122,136 | ≥2400 | ≥114 | 21 |
137Cs | DCCLXII | ≥2640 | ≥28 | 95 |
60Co | 1173,1332 | ≥5760 | ≥16 | 360 |
133Ba | 3,181,302,356 | ≥4560 | ≥88 | 52 |
2. Sensibilitas detectionis
Systema monitorium pedestrium et systema monitorium sarcinarum linearum
Pedester: Probabilitas detectionis f 90% celeritatis v=1.2m/s
Fasciculus linearis: probabilitas probationis f 90% celeritatis v = 1 m / s
fons radioactivus | Actio vel qualitas |
137Cs | 0.08MBq |
60Co | 0.02MBq |
241Am | 2.27MBq |
3. Efficacia detectoris neutronici contra interferentiam
Cum fons 60Co dosis ratem in centro geometrico superficiei detectoris neutronici systematis monitorii maiorem quam 120 Sv/h generat, systema monitorium alarmum neutronicum excitare non debet.
4. Ratio falsae alarmis: 0.01% (, neutron)
Probabilitas alarmi systematis detectionis causatae a substantiis non radioactivis vel non-SNM
5. proprietates oneris excessivi
Cum dosis superficialis detectoris > 120 Sv/h est, systema monitorium statum alarmi servabit et ad statum fundamentalem redibit, et tempus emissionis alarmi minus quam 60s erit.
6. Constantia sensibilitatis
Intra ambitum areae detectionis
Pedester ± 25% Fasciculus Lineae ± 25%
Frequentia misalarmorum
In ambitu stabili:
Sensore spatiali utere, decies milies, falsorum alarmorum proportio 1.
Sine sensore occupationis adhibito, proportio falsae alarmis et proportio erroneae identificationis semel intra 12 horas adhibentur.
Responsio Radiationis γ
Occupat quinquagies, alarma quadagies novem
Ultra spatium
Supra 100 v S/h, signum radiationis altae emittitur et intra 1 minutum postquam fons discedit removetur.
Alarma neutronica radiatione inducta
Nulla alarma neutronica excitatur cum dosis radii gamma ad 100 Sv/h pervenit.
Influentia secundaria
Cum mutatio fundi satis magna est ut magnam mutationem in probabilitate alarmi efficiat, systema monitorium monitum emittet.
Recognitio nuclidorum
Nuclidum naturale | 40K.226Ra,232Th |
Nuclidum industriale | 241Sum,137Cs.60Co.57Co.22Na,133Ba,54Mn,88Y |
Nuclida medica | 131Ego,201Tl,203Mercurium18F.99mTc,99Mo,192Ir |
Materiae nucleares speciales | 57Co.CLIIEu,238U |
Nota: Identificatio nuclidorum et detectio neutronum facultativae sunt, non in systemate normali.

Figura 1. Monitorium radiationis sarcinarum et pedestrium