Professional elit deprehensio radiorum

XV Annos Vestibulum Usus
vexillum

RJ12 series canalis genus pedestrem, linea sarcina radiorum magna armorum

Description:

RJ12 pedestris et sarcina radioactiva magnae instrumenti est magna instrumenta radioactiva pro peditibus et impedimentis.Proprietates summae sensibilitatis, late detectionis et temporis brevi responsionis, ac percipere potest radiorum radiorum automaticum terrorem, notitias repositionis latae et alia munera.Systema agnitionis faciei libitum, cum positione latae sententiae coniuncta, personas suspectas in area scopum collocare potest.Adhiberi possunt in variis locis canales importationis et educendi, sicut terminus terrae, aeriportus, statione ferriviaria, statione subway, malla shopping, etc.


Product Detail

Product Tags

technica pluma

① BIN (Bin Lepidium sativum) background technologiam ignorat

② MCA multispectrum analyser, proprium SIGMA algorithm statisticum

NORMA munus (40K) Velox distinguere inter nucleos communes artificiales et naturales (e. g40K、232Th)

Nuclide agnitio functionis (cum sodium iodide probe / ad libitum)

⑤ Coniungendo sodium iodide detectoris et MCA energia multichannel spectrometri analystoris accurate distinguere potest inter nuclides, nucleas industriales et radionuclides naturales.

Naturalis nuclide 40K、226Ra、232Th
Industriae nuclei 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y
Nuclides medicae 131EGO,201Tl、203Hg、18F、99mTc、99Mo、192Ir
Specialis materiae nuclei 57Co、152Eu,238U

summus celeritate sampling (celeriter: 200ms)

 Detector principalis technica Indicatoress

nomen project Parameter informationes
Genera detectors Plate plastic scintillator + sonitus humilis photomultiplier tube
Detector volumen 5,10,15 ad libitum cum duali specillo (ostium default duali probe)
Maximum saltum rate 106cps
industria range 25keV~3MeV
sensus m5000cps / (Sv / h) (10 L, relative137Cs)
Deprehensio minus terminus Facultatem deprehendendi radiorum supra curriculum 5nSv / h
Ad libitum, tubus neutron
  • Specillum genus: longa vita3Ille neutron detector (1 atmosphaerica seu pressura ad libitum)
  • Energy range: 0.025eV (calidum neutron) ~14MeV
  • Vita comitis: 1017Comitem
  • Deprehensio efficax area magnitudinis: 50mm 600mm, 25mm 600mm, 57mm 1054mm libitum est;
  • Sensibilitas: 75 cps / Sv / h (relativum ad alterum) m252Cf.
  • Ratio comitem: <5cps
Dinnuclide agnitio libitum
  • Detector type: Gallia SAN Gobain mole sodium iodide detector + potassium vicus photomultiplicius
  • Detector voluminis: 1 l, 2 l ad libitum, duplicibus rimandis instructum
  • Maximum saltum rate: 106cps
  • Energy range: 25keV~3MeV
  • Sensivity: 20000 cps / (Sv / h) (2 L, relativo137Cs)

De indicibus technicis principalis systematis

1. Deprehensio Static efficientiam (AB)

A. Static deprehensio systema vigilantia pedestrem efficientiam

ardens fons Pelagus industriakeV

Deprehensio stabilis efficientiam

Dose rate ad 1.5m / (nSv.h-1/MBq
s-1/MBq s-1/(nSv.h-1)
241Am 60 ≥220 ≥94 2.3
57Co 122,136 ≥840 ≥90 9.3
137Cs 662 ≥960 ≥23 42
60Co 1173,1332 ≥1800 ≥11 160
133Ba 3,181,302,356 ≥1680 ≥73 23

Effunde;

1. 252Cf vexillum neutronum fons testium cum valido neutro fonte 12000 / s (1 ± 20%) ponitur in loco referentiae detectoris.

2. Neutron rate occurret postulationi quantitatis comitialis> 100 (1 ± 20%) / s

Static deprehendendi efficientiam B-row sarcina ratio magna

ardens fons Pelagus industriakeV

Deprehensio stabilis efficientiam

Dose rate ad 1.5m / (nSv.h-1/MBq
s-1/MBq s-1/(nSv.h-1)
241Am 59.5 ≥480 ≥92 5.2
57Co 122,136 ≥2400 ≥114 21
137Cs 662 ≥2640 ≥28 95
60Co 1173,1332 ≥5760 ≥16 360
133Ba 3,181,302,356 ≥4560 ≥88 52

2. Deprehensio sensus

Pedestria magna ratio et linea sarcina magna ratio

Pedestrem: Deprehensio probabiliter f XC% celeritas v = 1.2m / s *

Linea sarcina: probe probabiliter f XC% celeritas v = 1m / s *

ardens fons Actio seu species
137Cs 0.08MBq
60Co 0.02MBq
241Am 2.27MBq

3. Anti-inpedimento neutronis observantia detector

Cum 60Co fons dosem generat in centro geometricae superficiei neutronis detectoris systematis vigilantiae, maior quam 120 Sv / h, ratio vigilantia neutron terrorem felis non debet.

4. Falsus terror rate: 0.01% (, neutron)

Probabilitas deprehendendi ratio terrorem non-radioactive substantiae vel non-SNM

5. cultro characteres

Cum detector superficies dosis est> 120 Sv/h, ratio vigilantia terrorem conservabit et in statum curriculi reditum, et terror emissio temporis minor est quam 60s.

6. Sensibilitas constantia

In latitudine deprehendatur spatio

Pedestria ± 25% Line Pack ± 25%

Indicatores technica ad idem principalis nuclide (libitum)

Misalarm rate

Stabulo in ambitu:

Utere spatio sensori, 10000 temporibus, falsa terrore rate 1

Sine usura in sensorem occupantem, in rate falsa terrore ac misidentificatione semel in 12h . adhibita sunt

γ Radiation Responsio

Occupare 50 times, terror 49 times

Outrange

Plus 100 v S / h, terror altus radiorum emittitur et intra 1min post fontem foliorum emittitur

Neutron terror adductus radialis

Nullus neutron terrori utitur cum dosis γ-radii 100 Sv / h . attingit

Background influxum

Cum rerum curricula mutatio satis magna est ad probabilitatem magnam in terrore mutationem causandam, ratio vigilantia admonitionem promptam dabit

Nuclide agnitio

Naturalis nuclide 40K、226Ra、232Th
Industriae nuclei 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y
Nuclides medicae 131EGO,201Tl、203Hg、18F、99mTc、99Mo、192Ir
Specialis materiae nuclei 57Co、152Eu,238U

Nota: Nuclidis identificatio et deprehensio neutronis libitum est, non in systemate norma

Exemplar systematis

1

Figure 1. Package et pedestrem radialis magna

2

Figura 2. Radiatio pedestriani magna apparatu


  • Priora:
  • Deinde: